Drake TR-4C - receive problem
The old workhorse seldom gave problems on transmit.
A frequent receive problem was the receiver going dead on switching back to receive from transmit.
The problem was solved by replacing custom C145 (4 electrolytic capacitors housed in a can) with individual capacitors.
Capacitors drying out was the root cause.